Konto Kontakt
Din kurv
Black Weekop til −30 %endnu 7 d 02:05:27
DPD & FedEx – leveringsdato på produktsiden.
Brug for hjælp? DistriNode AI hjælper dig.

Conteg ventilationsmodul med 4 blæsere, reguleret

Conteg ventilationsmodul med 4 blæsere, reguleret
-9%
Black Week
Conteg ventilationsmodul med 4 blæsere, reguleret
2.337,23 kr.
2.560,58 kr.−9 %
PDF
PDF
Lagerstatus 2 Produktkode 3397306 Model DP-VEN-04-H Garanti 2 år

Levering & returnering

Forventet levering tirsdag den 8. december
Du holdes opdateret via vores detaljerede sporingssystem
Betalingsmuligheder
BetalingskortVisaMastercardApple PayGoogle PayBankoverførsel

Stil et spørgsmål – AI-assistenten svarer med det samme.

Beskrivelse

Data center operators and IT managers often face the challenge of maintaining optimal temperatures in densely packed server racks. The CONTEG DP-VEN-04-H is a 1U rack mount fan unit engineered to deliver active cooling where passive airflow falls short. With four thermostat-controlled axial fans, it automatically adjusts speed based on real-time temperature readings, ensuring your equipment stays within safe operating limits without manual intervention.

Key specifications

  • Mounting: 19-inch rack mount, 1U height
  • Number of fans: 4 axial fans
  • Control: Thermostat-controlled with integrated temperature sensor
  • Maximum airflow: 480 m³/h
  • Maximum noise level: 50 dB(A)
  • Power supply: 230V AC, 50/60 Hz, 45 W consumption
  • Power connector: IEC C14 inlet
  • Material: Steel, black (RAL 9005)
  • Operating temperature: 0°C to +50°C
  • Protection class: IP20
  • Certifications: CE, RoHS

Why choose it

This fan unit is built to handle the thermal demands of modern server and network cabinets. The automatic speed regulation based on internal temperature not only optimizes cooling performance but also reduces energy consumption and noise during low-load periods. Its robust steel construction and standard 1U form factor make it a durable and space-efficient addition to any rack.

Ideal use cases

  • Cooling high-density server racks in data centers
  • Enhancing airflow in network cabinets with active equipment
  • Supplementing cooling in IT closets or edge computing environments
  • Preventing hot spots in racks with limited ventilation

Good to know

The unit connects via a standard IEC C14 inlet, allowing easy integration with common rack power distribution units. Installation is straightforward in any 19-inch rack, and the black finish matches most rack aesthetics. Regular maintenance is minimal—just ensure the fans remain free of dust for optimal performance.

Specifikationer

Specifikationer
AC-indgangsfrekvens
50/60 Hz
Adgangskodebeskyttelse
Nej
Bredde
482 mm
Driftstemperatur (T-T)
0 - 50 °C
Dybde
250 mm
Formfaktor
1U rackmontering
Højde
44 mm
Kabellængde
Nej
Kategori
Rackventilatorenhed
Kædeforbindelse
Nej
LED-indikatorer
Power, Fan status
Maks. strøm
10 A
Model
DP-VEN-04-H
MPN
DP-VEN-04-H
Mærke
CONTEG
Overensstemmelsescertifikater
CE, RoHS
Overspændingsbeskyttelse
Nej
Produktfarve
Sort
Rackkapacitet
1U
Strømstik
IEC C14
Type
Ventilatorenhed
Tænd/sluk-kontakt
Ja
Vægt
3.5 kg
Prishistorik for de seneste 6 måneder
Conteg ventilationsmodul med 4 blæsere, reguleret
Aktuel
2.337,23 kr.
Laveste 7 d.
2.337,23 kr.
Højeste 7 d.
2.560,58 kr.
Ændring 24 timer
-99,88 kr.   -4%
Ændring 7 d.
-79,63 kr.   -3%
Ændring 30 d.
-223,35 kr.   -9%

Skriv en anmeldelse

Bedømmelse *
Bemærk: HTML-kode understøttes ikke!

Flere CONTEG-produkter i denne kategori

4

Populære produkter i denne kategori

8
Sælger: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litauen · Virksomhedsnr. 303192950 · Momsnr. LT100008198612 · Afsendes fra EU (Litauen)
WhatsApp
Messenger
Hej, jeg er DistriNodes AI-assistent. Jeg hjælper dig gerne med at finde produkter, sammenligne muligheder, lave PDF-tilbud eller oprette supporthenvendelser.
Alle kategorier