Konto Kontakt
Din kurv
DPD & FedEx – leveringsdato på produktsiden.
Brug for hjælp? DistriNode AI hjælper dig.

Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W

Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
4.248,01 kr.
PDF
PDF
Lagerstatus 3 Produktkode 2554637 Model DN-170132 Garanti 2 år

Levering & returnering

Forventet levering torsdag den 26. november
Du holdes opdateret via vores detaljerede sporingssystem
Betalingsmuligheder
BetalingskortVisaMastercardPayPalApple PayGoogle PayBankoverførsel

Stil et spørgsmål – AI-assistenten svarer med det samme.

Beskrivelse

The DIGITUS OnLine UPS DN-170132 is a tower uninterruptible power supply delivering 3000 VA / 3000 W of continuous, double-conversion power conditioning for servers, network equipment and critical workstations. The OnLine topology provides pure sine wave output and continuous voltage regulation, isolating connected devices from mains disturbances and offering battery-backed runtime for safe shutdowns.

Advantages

This UPS provides zero ms transfer time to battery, pure sine wave output with tight voltage regulation and a wide input voltage range that reduces battery use under unstable mains. The compact tower design saves space while offering high performance, integrated monitoring interfaces (USB, RS-232 and optional SNMP/Webcard) and optimized charging management for extended battery life and fast recovery after outages.

Suitable for

  • Small and medium server rooms
  • Critical network infrastructure and switches
  • Workstations handling sensitive or business‑critical data
  • Office environments requiring uninterrupted operation

When it may not be suitable

This UPS is designed for environments with moderate rack/tower space and typical office or server-room cooling; it may be less suitable where a rack-mounted form factor is required or where very low-noise, ultra-compact desktop units are preferred. Environments above 1000 m altitude require power de-rating and may limit available output.

Key specifications

  • Topology: Online double-conversion
  • Output capacity: 3000 VA / 3000 W
  • Input voltage: 208 / 220 / 230 / 240 Vac; operating range 110–300 Vac (176–264 Vac at 100% load)
  • Input connector: IEC60320 C20
  • Output sockets: 4 × IEC60320 C13 (max. 10 A per outlet)
  • Voltage regulation: ±1 %
  • Output waveform: Pure sine wave
  • Switchover time: 0 ms to battery; inverter to bypass approx. 4 ms
  • Efficiency: up to 92% (mains), up to 97% (ECO mode)
  • Battery: VRLA lead‑acid, 6 × 12 V / 9.0 Ah (72 Vdc total)
  • Typical recharge time: ~4 hours to 90%
  • Charging current (max): 6 A
  • Generator compatibility and cold-start capable
  • Communication: USB, RS-232; optional SNMP/Webcard for remote monitoring
  • Protections: short circuit, overload, overheating
  • Operating temperature: 0–40 °C; storage: -25–55 °C
  • Humidity: 20–95% RH (0–40 °C, non‑condensing)
  • Operating altitude: <1000 m (power reduction required above 1000 m up to 3000 m)
  • Noise level: <50 dB
  • Dimensions (W×D×H): 191 × 460 × 337 mm
  • Weight: 24.5 kg

How to use

Install the UPS on a stable, ventilated surface and connect the input to a compatible mains outlet using the IEC C20 connector. Plug your devices into the IEC C13 outlets, observing the 10 A per-socket limit and overall UPS load capacity. Use the integrated display and local communication ports (USB or RS-232) for monitoring; if remote management is required, install the optional SNMP/Webcard. In case of mains failure the UPS switches to battery with no interruption, allowing controlled shutdown of connected equipment.

What to consider before purchase

  • Ensure total connected load does not exceed 3000 W and per-socket limit (10 A)
  • Check available space and ventilation for a 191×460×337 mm tower unit
  • Consider altitude of installation (power reduction above 1000 m)
  • Decide if optional SNMP/Webcard is required for remote monitoring
  • Plan for battery replacement over time (VRLA/lead‑acid technology)

Recommendations

For best results, operate the UPS in a temperature-controlled environment (0–40 °C), avoid excessive dust and humidity, perform regular battery health checks, and allow a full recharge after extended outages. Use the optional SNMP/Webcard for centralized monitoring in critical infrastructures.

How to use

Install the UPS on a stable, ventilated surface and connect the input to a compatible mains outlet using the IEC C20 connector. Plug your devices into the IEC C13 outlets, observing the 10 A per-socket limit and overall UPS load capacity. Use the integrated display and local communication ports (USB or RS-232) for monitoring; if remote management is required, install the optional SNMP/Webcard. In case of mains failure the UPS switches to battery with no interruption, allowing controlled shutdown of connected equipment.

Recommendations

For best results, operate the UPS in a temperature-controlled environment (0–40 °C), avoid excessive dust and humidity, perform regular battery health checks, and allow a full recharge after extended outages. Use the optional SNMP/Webcard for centralized monitoring in critical infrastructures.

Vigtigste egenskaber
  • Small and medium server rooms
  • Critical network infrastructure and switches
  • Workstations handling sensitive or business‑critical data
  • Office environments requiring uninterrupted operation
  • Topology: Online double-conversion
  • Output capacity: 3000 VA / 3000 W
  • Input voltage: 208 / 220 / 230 / 240 Vac; operating range 110–300 Vac (176–264 Vac at 100% load)
  • Input connector: IEC60320 C20
  • Output sockets: 4 × IEC60320 C13 (max. 10 A per outlet)
  • Voltage regulation: ±1 %
  • Output waveform: Pure sine wave
  • Switchover time: 0 ms to battery; inverter to bypass approx. 4 ms
  • Efficiency: up to 92% (mains), up to 97% (ECO mode)
  • Battery: VRLA lead‑acid, 6 × 12 V / 9.0 Ah (72 Vdc total)
  • Typical recharge time: ~4 hours to 90%
  • Charging current (max): 6 A
  • Generator compatibility and cold-start capable
  • Communication: USB, RS-232; optional SNMP/Webcard for remote monitoring
  • Protections: short circuit, overload, overheating
  • Operating temperature: 0–40 °C; storage: -25–55 °C
  • Humidity: 20–95% RH (0–40 °C, non‑condensing)
  • Operating altitude:
  • Noise level:
  • Dimensions (W×D×H): 191 × 460 × 337 mm
  • Weight: 24.5 kg
  • Ensure total connected load does not exceed 3000 W and per-socket limit (10 A)
  • Check available space and ventilation for a 191×460×337 mm tower unit
  • Consider altitude of installation (power reduction above 1000 m)
  • Decide if optional SNMP/Webcard is required for remote monitoring
  • Plan for battery replacement over time (VRLA/lead‑acid technology)
Prishistorik for de seneste 6 måneder
Tårn-USV DIGITUS OnLine DN-170132 — 3000 VA / 3000 W
Aktuel
4.248,01 kr.
Laveste 7 d.
4.216,98 kr.
Højeste 7 d.
4.266,20 kr.
Ændring 24 timer
-0,41 kr.   0%
Ændring 7 d.
+31,03 kr.   +1%
Ændring 30 d.
+194,83 kr.   +5%

Skriv en anmeldelse

Bedømmelse *
Bemærk: HTML-kode understøttes ikke!

Flere DIGITUS-produkter i denne kategori

7

Populære produkter i denne kategori

8
Sælger: UAB KUR LT · Gariūnų g. 57-14, LT-02300 Vilnius, Litauen · Virksomhedsnr. 303192950 · Momsnr. LT100008198612 · Afsendes fra EU (Litauen)
WhatsApp
Messenger
Hej, jeg er DistriNodes AI-assistent. Jeg hjælper dig gerne med at finde produkter, sammenligne muligheder, lave PDF-tilbud eller oprette supporthenvendelser.
Alle kategorier